C O – Experts Low Level C O “Health” Monitors are designed to “Put you in Control of, NOT at the Mercy of” Chronic Low Level Carbon Monoxide Poisoning.                                     

 

 

Low Level C O warnings at 7, 10, 25, 35, 50, 70 & 100 PPM in “REAL TIME”.

NO “MUST NOT” alarm periods of C O exposure time, or deadly exposure time delays required in UL-2034 Listed C O alarms. Plus detailed data storage of the “Time Lines” of C O exposures, plus Hush / Silence cycles at every alarm level.                                      

            

 

·       Low Level C O warning start at 7 PPM and all audible and visual warnings are in “REAL TIME”, no mandatory delays; thereby making this Low Level C O Monitor also a terrific smoldering fire detection addition to your home protection system.

 

·       Audible alarm “Hush / Silence” cycles based on C O PPM level present.

 

·       Automatic “Hush / Silence” override if C O present rises to next level.

 

·       Data storage of the Time Lines of C O exposure: High / Peak Level, duration of exposure in days, hours and minutes, the resulting COHb from such exposure.

 

·       Quick, simple methods of clearing stored data and ending hush / silence cycle  if desired.

 

·       Failsafe design including sensor failure / End of Life warning in addition to a “Kill Switch” at 7.5 years.

 

·       Fie year warranty on all parts as long as components are commercially available.                       

 

 

 

Features & Benefits that put you in CONTROL of your C O Incident    

 

 

CO – Experts Low Level CO “Health” Monitors provide you with VERY EARLY Warning of the presence of Carbon Monoxide, long before a serious health or life safety threat exists.

 

 

C O – Experts tell you when it is time to call your Professional Heating Contractor to investigate the source of your C O and correct the problem immediately, instead of receiving a much later Warning from a UL-2034 Listed C O alarm that most likely will not tell you until it is time to call 911 for a “Ride” to the nearest hospital having a Hyperbaric Therapy Chamber and Treatment Center.

 

 

UL-2034 Listed C O alarms are tested at 70, 150 and 400 PPM and NONE of these Warning are sounded in “REAL TIME”, all audible alarms have “Must Not Alarm” periods; as well as delays.

 

For example, at 70 PPM, a UL-2034 Listed C O alarm “Must Not Alarm” in the first hour, 60 minutes, and the audible warning may be delayed up to 4 hours.                                               

 

 

To make this data even worse than it seems at first glance is the fact that this also

 

means that UL-2034 REQUIRES NO TESTING below 65 PPKM.           

 

 

You Choose the “Real Time” Audible Alarm Warning Level, 10 or 25 PPM.                                           

 

 

All C O – Experts Visual / Display WARNING starts at 7 PPM                               

 

 

Audible Alarm Levels                          Alarm “HUSH” CYCLES                                  

 

 

0 to 6 PPM …. No Warnings                   None

 

10 to 24 PPM                                          24 hours

 

25 to 34 PPM                                          1 hour                                                                         

 

35 to 49 PPM                                          1 hour

 

50 to 69 PPM                                          1 hour

 

70 PPM to  "HI"                                       4 Minutes

                                        

                                                  

When the "Hush" is employed, the audible alarm is silenced for the designated period of time: however, the visual display continues to show the current level of CO present. IF, after any "Hush", the CO levels present continue to rise to the next higher level, the Monitor will automatically OVER-Ride the "Hush" and reactivate the audible alarm at the higher, faster, level   

To activate / employ the “Hush” feature, as soon as the Monitor’s audible alarm warning cycle competes the third of its 3 beeping cycles, simply touch / push the test / hush / reset button and the  Display window will show “Acc”, to acknowledge your request the “Hush” to be employed. The Monitor will then show “SIL”, to indicate that AFTER the regular three cycle beeping, [which follows every push of the “Test” button], your Monitor will be SILENT for the specified period of time, unless the CO present rises to the next higher level of warning. Removal of the battery will immediately cancel the “Hush” feature.   

  

 

Important additional information about your C O Monitor:        

                             

 

CO is almost ALWAYS picked up by Monitors while being transported, from both the UPS Trucks and especially from the Propane Forklifts being used in the terminals. Therefore, there may be C O accumulated inside the housing and in the sensor when it is initially removed from its individual box that will cause an alarm within a minute or so of initially installing the battery. Before installing any Monitor, the “Stored Data” should be electronically cleared.                            

 

                              

To CLEAR / ERASE all stored data, you simply depress the Test / Hush / Clear button, and continue to hold it depressed until the Green L.E.D. illuminates with a continuous, [not blinking],  green light. Release the button, and the Monitor will immediately sound a long single beep, and the LCD will display “Clr”, indicating that all previously stored data has now been erased.      

                             

 

Removal of the battery will immediately cancel the “Hush Cycle” feature; however, it is very important to remember that removal of the battery does NOT “clear / erase” the stored data saved in your Monitor. This can be a very important feature in my opinion because it prevents you from accidentally losing this important stored data which you might need to show to the 1st Responders, the Medical, [Hospital or Hyperbaric Therapy  people that could possibly become involved or perhaps a Liability / Trial Attorney. The stored data is cleared / erased ONLY when you intentionally / mechanically clear the stored data, as instructed above.